Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Checkout our iOS App for a better way to browser and research.

§ 405.52 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) For plants processing more than 25,000 lb/day of milk equivalent (more than 2,600 lb/day of BOD5 input).

Expand Table
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed -
Metric units (kilograms per 1,000 kg of BOD5 input)
BOD5 6.70 2.680
TSS 10.050 4.020
pH (1) (1)
English units (pounds per 100 lb of BOD5 input)
BOD5 0.670 0.268
TSS 1.005 .402
pH (1) (1)

(b) For plants processing 25,000 lb/day or less of milk equivalent (less than 2,600 lb/day of BOD5 input).

Expand Table
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed -
Metric units (kilograms per 1,000 kg of BOD5 input)
BOD5 8.926 4.463
TSS 13.388 6.694
pH (1) (1)
English units (pounds per 100 lb of BOD5 input)
BOD5 0.893 0.446
TSS 1.339 .669
pH (1) (1)