Effluent limitations attainable by the application of the best practicable control technology currently available (BPT).

Checkout our iOS App for a better way to browser and research.

§ 432.82 Effluent limitations attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BPT:

(a) Facilities that generate no more than 50 million pounds per year of finished products must achieve the following effluent limitations:

Expand Table

Effluent Limitations

[BPT]

Regulated
parameter
Maximum daily1 Maximum monthly avg.1
BOD5 0.62 0.31
Fecal Coliform (2) (3)
O&G4 0.22 0.11
TSS 0.74 0.37

(b) Facilities that generate more than 50 million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G, and TSS specified in paragraph (a) of this section.