Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Checkout our iOS App for a better way to browser and research.

§ 405.42 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) For plants processing more than 175,000 lb/day of milk equivalent (more than 18,180 lb/day of BOD5 input).

Expand Table
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed -
Metric units (kilograms per 1,000 kg of BOD5 input)
BOD5 1.375 0.550
TSS 2.063 .825
pH (1) (1)
English units (pounds per 100 lb of BOD5 input)
BOD5 0.138 0.055
TSS 0.206 .083
pH (1) (1)

(b) For plants processing 175,000 lb/day or less of milk equivalent (less than 18,180 lb/day of BOD5 input).

Expand Table
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed -
Metric units (kilograms per 1,000 kg of BOD5 input)
BOD5 1.825 0.913
TSS 2.738 1.369
pH (1) (1)
English units (pounds per 100 lb of BOD5 input)
BOD5 0.183 0.091
TSS .274 .137
pH (1) (1)

[39 FR 18597, May 28, 1974, as amended at 60 FR 33933, June 29, 1995]