I-1 Condition 2, I-2NSd, e, fUL16065556555656565655040
SUL18085
I-4NSd, gUL16065556555656565655040
SUL1808575857518012085857060
RhNSdUL16065556555656565655040
S13D606060606060606060605040
S13R606060606060606060606060
SUL1808575857518012085857060
For SI: 1 foot = 304.8 mm UL = Unlimited; NS = Buildings not equipped throughout with an automatic sprinkler system; S = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1; S13R = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.2; S13D = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.3. a. See Chapters 4 and 5 for specific exceptions to the allowable height in this chapter. b. See Section 903.2 for the minimum thresholds for protection by an automatic sprinkler system for specific occupancies. c. New Group H occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.5. d. The NS value is only for use in evaluation of existing building area in accordance with the IEBC. e. New Group I-1 and I-3 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6. For new Group I-1 occupancies, Condition 1, see Exception 1 of Section 903.2.6. f. New and existing Group I-2 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6 and Section 1103.5 of the International Fire Code. g. New Group I-4 occupancies see Exceptions 2 and 3 of Section 903.2.6. h. New Group R occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.8."
(2) In IBC, Table 504.4, "Allowable Number of Stories Above Grade Planea, b" delete Type IV and replace it with the following, in relation to the occupancy classification and footnotes as indicated:
OCCUPANCY CLASSIFICATIONTYPE OF CONSTRUCTION
SEE FOOTNOTESTYPE IV
ABCHT
A-1NS3333
S9644
A-2NS3333
S181264
A-3NS3333
S181264
A-4NS3333
S181264
A-5NS111UL
SULULULUL
BNS5555
S181296
ENS3333
S9644
F-1NS3334
S10755
F-2NS5555
S12866
H-1NSc, dNPNPNP1
S111
H-2NSc, d1112
S222
H-3NSc, d3334
S444
H-4NSc, d5555
S8766
H-5NSc, d2223
S333
I-1 Condition 1NSd, e4444
S10755
I-1 Condition 2NSd, e3334
S1064
I-2NSd, fNPNPNP1
S751
I-3NSd, e2222
S7533
I-4NSd, g3333
S9644
MNS4444
S12865
R-1h NSd4444
S13R
S181285
R-2hNSd4444
S13R
S181285
R-3hNSd4444
S13D
S13R
S181255
R-4hNSd4444
S13D
S13R
S181255
S-1NS4444
S10755
S-2NS4444
S12855
UNS4444
S9655
UL = Unlimited; NP = Not Permitted; NS = Buildings not equipped throughout with an automatic sprinkler system; S = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1; S13R = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.2; S13D = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.3. a. See Chapters 4 and 5 for specific exceptions to the allowable height in this chapter. b. See Section 903.2 for the minimum thresholds for protection by an automatic sprinkler system for specific occupancies. c. New Group H occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.5. d. The NS value is only for use in evaluation of existing building height in accordance with the IEBC. e. New Group I-1 and I-3 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6. For new Group I-1 occupancies, Condition 1, see Exception 1 of Section 903.2.6. f. New and existing Group I-2 occupancies are required to be protected by an automatic sprinkler system in accordance with Sections 903.2.6 and 1103.5 of the International Fire Code. g. For new Group I-4 occupancies, see Exceptions 2 and 3 of Section 903.2.6. h. New Group R occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.8."
(3) In IBC, Table 506.2, "Allowable Area Factor (At = NS, S1, S13R, S13D or SM, as applicable) in Square Feeta, b" delete Type IV and replace it with the following, in relation to the occupancy classification and footnotes as indicated:
"OCCUPANCY CLASSIFICATIONSEE FOOTNOTESTYPE OF CONSTRUCTION
TYPE IV
ABCHT
A-1NS45,00030,00018,75015,000
S1180,000120,00075,00060,000
SM135,00090,00056,25045,000
A-2NS45,00030,00018,75015,000
S1180,000120,00075,00060,000
SM135,00090,00056,25045,000
A-3NS45,00030,00018,75015,000
S1180,000120,00075,00060,000
SM135,00090,00056,25045,000
A-4NS45,00030,00018,75015,000
S1180,000120,00075,00060,000
SM135,00090,00056,25045,000
A-5NSULULULUL
S1
SM
BNS108,00072,00045,00036,000
S1432,000288,000180,000144,000
SM324,000216,000135,000108,000
ENS76,50051,00031,87525,500
S1306,000204,000127,500102,000
SM229,500153,00095,62576,500
F-1NS100,50067,00041,87533,500
S1402,000268,000167,500134,000
SM301,500201,000125,625100,500
F-2NS151,500101,00063,12550,500
S1606,000404,000252,500202,000
SM454,500303,000189,375151,500
H-1NSc10,50010,50010,50010,500
S1
H-2NSc10,50010,50010,50010,500
S1
SM
H-3NSc25,50025,50025,50025,500
S1
SM
H-4NSc, d72,00054,00040,50036,000
S1288,000216,000162,000144,000
SM216,000162,000121,500108,000
H-5NSc, d72,00054,00040,50036,000
S1288,000216,000162,000144,000
SM216,000162,000121,500108,000
I-1NSd, e54,00036,00018,00018,000
S1216,000144,00072,00072,000
SM162,000108,00054,00054,000
I-2NSd, f36,00024,00012,00012,000
S1144,00096,00048,00048,000
SM108,00072,00036,00036,000
I-3NSd, e36,00024,00012,00012,000
S1144,00096,00048,00048,000
SM108,00072,00036,00036,000
I-4NSd, g76,50051,00025,50025,500
S1306,000204,000102,000102,000
SM229,000153,00076,50076,500
MNS61,50041,00025,62520,500
S1246,000164,000102,50082,000
SM184,500123,00076,87561,500
R-1hNSd61,50041,00025,62520,500
S13R
S1246,000164,000102,50082,000
SM184,500123,00076,87561,500
R-2hNSd61,50041,00025,62520,500
S13R
S1246,000164,000102,50082,000
SM184,500123,00076,87561,500
R-3hNSdULULULUL
S13D
S13R
S1
SM
R-4hNSd61,50041,00025,62520,500
S13D
S13R
S1246,000164,000102,50082,000
SM184,500123,00076,87561,500
S-1NS76,50051,00031,87525,500
S1306,000204,000127,500102,000
SM229,500153,00095,62576,500
S-2NS115,50077,00048,12538,500
S1462,000308,000192,500154,000
SM346,500308,000144,375115,500
UNSi54,00036,00022,50018,000
S1216,000144,00090,00072,000
SM162,000108,00067,50054,000
For SI: 1 square foot = 0.0929 m2. UL = Unlimited; NP = Not Permitted; NS = Buildings not equipped throughout with an automatic sprinkler system; S1 = Buildings a maximum of one story above grade plane equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1; SM = Buildings two or more stories above grade plane equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1; S13R = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.2; S13D = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.3. a. See Chapters 4 and 5 for specific exceptions to the allowable height in this chapter. b. See Section 903.2 for the minimum thresholds for protection by an automatic sprinkler system for specific occupancies. c. New Group H occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.5. d. The NS value is only for use in evaluation of existing building area in accordance with the IEBC. e. New Group I-1 and I-3 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6. For new Group I-1 occupancies, Condition 1, see Exception 1 of Section 903.2.6. f. New and existing Group I-2 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6 and Section 1103.5 of the International Fire Code. g. For New Group I-4 occupancies see Exceptions 2 and 3 of Section 903.2.6. h. New Group R occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.8. i. The maximum allowable area for a single-story nonsprinklered Group U greenhouse is permitted to be 9,000 square feet, or the allowable area shall be permitted to comply with Table C102.1 of Appendix C."
(4) In IBC, Section 508.4.4 is deleted and replaced with the following: "508.4.4 Separation. Individual occupancies shall be separated from adjacent occupancies in accordance with Table 508.4."
(5) In IBC, Section 508.4.4.1 is deleted and replaced with the following: "508.4.4.1 Construction. Required separations shall be fire barriers constructed in accordance with Section 707 or horizontal assemblies constructed in accordance with Section 711, or both, so as to completely separate adjacent occupancies. Mass timber elements serving as fire barriers or horizontal assemblies to separate occupancies in Type IV-B or IV-C construction shall be separated from the interior of the building with an approved thermal barrier consisting of a minimum of 1/2 inch (12.7 mm) gypsum board or a material that is tested in accordance with and meets the acceptance criteria of both the Temperature Transmission Fire Test and the Integrity Fire Test of NFPA 275."
(6) In IBC, Section 509, a new section is added as follows: "509.4.1.1 Type IV-B and IV-C construction. Where Table 509 specifies a fire-resistance-rated separation, mass timber elements serving as fire barriers or a horizontal assembly in Type IV-B or IV-C construction shall be separated from the interior of the incidental use with an approved thermal barrier consisting of a minimum of 1/2 inch (12.7 mm) gypsum board or a material that is tested in accordance with and meets the acceptance criteria of both the Temperature Transmission Fire Test and the Integrity Fire Test of NFPA 275."