11-10-10. Builder's energy efficiency disclosure statement.
The disclosure form required in §11-10-8 shall read as follows:
BUILDER'S ENERGY EFFICIENCY DISCLOSURE STATEMENT
Builder ______________________________________________________
Property Address ______________________________________________
______________________________________________
This Disclosure Statement concerns the real property identified above situated in the City of _______________ County of ____________, State of South Dakota.
Part 1. Builder shall provide the following information about the new residential building:
1. Has this new residential building been built or will it be built to meet the energy efficiency standards of the International Energy Conservation Code of 2009 (IECC 2009)?
Yes ______ No ______
2. Has this new residential building received or will it receive any other energy efficient certification?
Yes ______ No ______
If yes, which certification(s): ______________________________________
Part 2. Builder shall describe the following energy efficiency elements of the new residential building:
Actual | 2009 IECC* | 2009 IECC* | |
Value | Zone 5 | Zone 6 | |
Wall Insulation R-Value | ________ | R-20 (or R-13 | R-20 (or R-13 |
cavity + R-5 insulated | cavity + R-5 insulated | ||
sheathing) | sheathing) | ||
Attic Insulation R-Value | ________ | R-38 | R-49 |
Foundation Insulation R-Value | |||
Basement Walls | ________ | R-10/13** | R-15-19** |
Crawlspace Walls | ________ | R-10/13** | R-10/13** |
Slab-on-Grade | ________ | R-10, 2 ft. depth | R-10, 4 ft. depth |
Floors over Unheated Spaces | ________ | R-30 | R-30 |
Window U-Value | ________ | 0.35 | 0.35 |
Door U-Value | ________ | 0.35*** | 0.35*** |
Part 3. Builder shall provide the following information about equipment:
1. Does the new residential building contain an Energy Star certified:
a. Water heater?
Yes ______ No ______
b. Heating system (furnace, heat pump, or other)?
Yes ______ No ______
c. Cooling system (air conditioner, heat pump, or other)?
Yes ______ No ______
Part 4. Builder's Notes and Comments:
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
*IECC stands for International Energy Conservation Code.
**The first R-Value applies to continuous insulation; the second to framing cavity insulation.
***One opaque door per building is exempt from this requirement.
Source: SL 2009, ch 63, §4; SL 2011, ch 72, §6.