Shunting sensitivity.
-
Law
-
CFR 49
-
Transportation
-
Other Regulations Relating to Transportation
-
Federal Railroad Administration, Department of Transportation
-
Rules, Standards, and Instructions Governing the Installation, Inspection, Maintenance, and Repair of Signal and Train Control Systems, Devices, and Appliances
-
Rules and Instructions: All Systems
-
Track Circuits
- Shunting sensitivity.
Each track circuit controlling home signal or approach locking shall be so maintained that track relay is in deenergized position, or device that functions as a track relay shall be in its most restrictive state if, when track circuit is dry, a shunt of 0.06 ohm resistance is connected across the track rails of the circuit, including fouling sections of turnouts.
[49 FR 3383, Jan. 26, 1984]