Individual specification requirements.

Checkout our iOS App for a better way to browser and research.

§ 179.101-1 Individual specification requirements.

In addition to § 179.100, the individual specification requirements are as follows:

DOT specification Insulation Bursting pressure (psig) Minimum plate thickness (inches) Test pressure (psig) Manway cover thickness Bottom outlet Bottom washout Reference
(179.***)
105A100ALW Yes 500 5/8 100 2 2 1/2 No No
105A200ALW Yes 500 5/8 200 2 2 1/2 No No
105A300ALW Yes 750 5/8 300 2 2 5/8 No No
105A100W Yes 500 3 9/16 100 2 1/4 No No
105A200W Yes 500 3 9/16 200 2 1/4 No No
105A300W Yes 750 1 11/16 300 7 2 1/4 No No
105A400W Yes 1,000 1 11/16 400 7 2 1/4 No No
105A500W Yes 1,250 1 11/16 500 2 1/4 No No 102-1, 102-2
105A600W Yes 1,500 1 11/16 600 2 1/4 No No 102-4, 102-17
109A100ALW Optional 500 5/8 100 2 2 1/2 No Optional
109A200ALW Optional 500 5/8 200 2 2 1/2 No Optional
109A300ALW Optional 750 5/8 300 2 2 5/8 No Optional
109A300W Optional 500 1 11/16 300 2 1/4 No Optional
112A200W Optional4 500 3 5 9/16 200 2 1/4 No No
112A340W Optional4 850 1 11/16 340 2 1/4 No No
112A400W Optional4 1,000 1 11/16 400 2 1/4 No No
112A500W Optional4 1,250 1 11/16 500 2 1/4 No No
114A340W Optional4 850 1 11/16 340 6 Optional Optional 103
114A400W Optional4 1,000 1 11/16 400 6 Optional Optional 103
120A200ALW Yes 500 5/8 200 2 2 1/2 Optional Optional 103
120A100W Yes 500 3 9/16 100 2 1/4 Optional Optional 103
120A200W Yes 500 3 9/16 200 2 1/4 Optional Optional 103
120A300W Yes 750 1 11/16 300 2 1/4 Optional Optional 103
120A400W Yes 1,000 1 11/16 400 2 1/4 Optional Optional 103
120A500W Yes 1,250 1 11/16 500 2 1/4 Optional Optional 103

[Amdt. 179-52, 61 FR 28679, June 5, 1996, as amended at 66 FR 45390, Aug. 28, 2001; 68 FR 75760, Dec. 31, 2003]


Download our app to see the most-to-date content.