In addition to § 179.100, the individual specification requirements are as follows:
| DOT specification | Insulation | Bursting pressure (psig) | Minimum plate thickness (inches) | Test pressure (psig) | Manway cover thickness | Bottom outlet | Bottom washout | Reference (179.***) |
|---|---|---|---|---|---|---|---|---|
| 105A100ALW | Yes | 500 | 5/8 | 100 | 2 2 1/2 | No | No | |
| 105A200ALW | Yes | 500 | 5/8 | 200 | 2 2 1/2 | No | No | |
| 105A300ALW | Yes | 750 | 5/8 | 300 | 2 2 5/8 | No | No | |
| 105A100W | Yes | 500 | 3 9/16 | 100 | 2 1/4 | No | No | |
| 105A200W | Yes | 500 | 3 9/16 | 200 | 2 1/4 | No | No | |
| 105A300W | Yes | 750 | 1 11/16 | 300 | 7 2 1/4 | No | No | |
| 105A400W | Yes | 1,000 | 1 11/16 | 400 | 7 2 1/4 | No | No | |
| 105A500W | Yes | 1,250 | 1 11/16 | 500 | 2 1/4 | No | No | 102-1, 102-2 |
| 105A600W | Yes | 1,500 | 1 11/16 | 600 | 2 1/4 | No | No | 102-4, 102-17 |
| 109A100ALW | Optional | 500 | 5/8 | 100 | 2 2 1/2 | No | Optional | |
| 109A200ALW | Optional | 500 | 5/8 | 200 | 2 2 1/2 | No | Optional | |
| 109A300ALW | Optional | 750 | 5/8 | 300 | 2 2 5/8 | No | Optional | |
| 109A300W | Optional | 500 | 1 11/16 | 300 | 2 1/4 | No | Optional | |
| 112A200W | Optional4 | 500 | 3 5 9/16 | 200 | 2 1/4 | No | No | |
| 112A340W | Optional4 | 850 | 1 11/16 | 340 | 2 1/4 | No | No | |
| 112A400W | Optional4 | 1,000 | 1 11/16 | 400 | 2 1/4 | No | No | |
| 112A500W | Optional4 | 1,250 | 1 11/16 | 500 | 2 1/4 | No | No | |
| 114A340W | Optional4 | 850 | 1 11/16 | 340 | 6 | Optional | Optional | 103 |
| 114A400W | Optional4 | 1,000 | 1 11/16 | 400 | 6 | Optional | Optional | 103 |
| 120A200ALW | Yes | 500 | 5/8 | 200 | 2 2 1/2 | Optional | Optional | 103 |
| 120A100W | Yes | 500 | 3 9/16 | 100 | 2 1/4 | Optional | Optional | 103 |
| 120A200W | Yes | 500 | 3 9/16 | 200 | 2 1/4 | Optional | Optional | 103 |
| 120A300W | Yes | 750 | 1 11/16 | 300 | 2 1/4 | Optional | Optional | 103 |
| 120A400W | Yes | 1,000 | 1 11/16 | 400 | 2 1/4 | Optional | Optional | 103 |
| 120A500W | Yes | 1,250 | 1 11/16 | 500 | 2 1/4 | Optional | Optional | 103 |
[Amdt. 179-52, 61 FR 28679, June 5, 1996, as amended at 66 FR 45390, Aug. 28, 2001; 68 FR 75760, Dec. 31, 2003]