Transmitters designed to operate in the 150-174 MHz and 421-512 MHz frequency bands must maintain transient frequencies within the maximum frequency difference limits during the time intervals indicated:
Time intervals1 2 | Maximum frequency difference3 |
All equipment | |
---|---|---|---|
150 to 174 MHz | 421 to 512 MHz | ||
Transient Frequency Behavior for Equipment Designed to Operate on 25 kHz Channels | |||
t14 | ±25.0 kHz | 5.0 ms | 10.0 ms |
t2 | ±12.5 kHz | 20.0 ms | 25.0 ms |
t34 | ±25.0 kHz | 5.0 ms | 10.0 ms |
Transient Frequency Behavior for Equipment Designed to Operate on 12.5 kHz Channels | |||
t14 | ±12.5 kHz | 5.0 ms | 10.0 ms |
t2 | ±6.25 kHz | 20.0 ms | 25.0 ms |
t34 | ±12.5 kHz | 5.0 ms | 10.0 ms |
Transient Frequency Behavior for Equipment Designed to Operate on 6.25 kHz Channels | |||
t14 | ±6.25 kHz | 5.0 ms | 10.0 ms |
t2 | ±3.125 kHz | 20.0 ms | 25.0 ms |
t34 | ±6.25 kHz | 5.0 ms | 10.0 ms |
[62 FR 2040, Jan. 15, 1997]