§ 90.214 Transient frequency behavior.

Transmitters designed to operate in the 150-174 MHz and 421-512 MHz frequency bands must maintain transient frequencies within the maximum frequency difference limits during the time intervals indicated:

Expand Table
Time intervals1 2 Maximum
frequency
difference3
All equipment
150 to 174 MHz 421 to 512 MHz
Transient Frequency Behavior for Equipment Designed to Operate on 25 kHz Channels
t14 ±25.0 kHz 5.0 ms 10.0 ms
t2 ±12.5 kHz 20.0 ms 25.0 ms
t34 ±25.0 kHz 5.0 ms 10.0 ms
Transient Frequency Behavior for Equipment Designed to Operate on 12.5 kHz Channels
t14 ±12.5 kHz 5.0 ms 10.0 ms
t2 ±6.25 kHz 20.0 ms 25.0 ms
t34 ±12.5 kHz 5.0 ms 10.0 ms
Transient Frequency Behavior for Equipment Designed to Operate on 6.25 kHz Channels
t14 ±6.25 kHz 5.0 ms 10.0 ms
t2 ±3.125 kHz 20.0 ms 25.0 ms
t34 ±6.25 kHz 5.0 ms 10.0 ms

[62 FR 2040, Jan. 15, 1997]