(a) You must demonstrate continuous compliance with the emissions limitations and work practice standards in § 63.7915 applicable to your affected transfer system by meeting the requirements in paragraphs (b) through (e) of this section as applicable to your transfer systems.
(b) You must demonstrate continuous compliance for each individual drain system using controls according to § 63.7915(b) by meeting the requirements in paragraphs (b)(1) through (5) of this section.
(1) Operating and maintaining the air emission controls for individual drain systems according to the requirements in § 63.962.
(2) Visually inspecting each individual drain system at least annually according to the requirements in § 63.964(a).
(3) Repairing defects according to the requirements in § 63.964(b).
(4) Recording the information specified in § 63.965(a).
(5) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(c) You must demonstrate continuous compliance for each transfer system using covers according to § 63.7915(c)(1) by meeting the requirements in paragraphs (c)(1) through (4) of this section.
(1) Operating and maintaining each cover and its closure devices according to the requirements in § 63.689(d)(1) through (5).
(2) Performing inspections of each cover and its closure devices for defects at least annually according to the requirements in § 63.695(d)(1) through (5).
(3) Repairing defects according to the requirements in § 63.695(5)
(4) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(d) You must demonstrate continuous compliance for each transfer system that consists of hard piping according to § 63.7915(c)(2) by meeting the requirements in paragraphs (d)(1) through (4) of this section.
(1) Operating and maintaining the pipeline to ensure that all joints or seams between the pipe sections remain permanently or semi-permanently sealed (e.g., a welded joint between two sections of metal pipe or a bolted and gasketed flange).
(2) Inspecting the pipeline for defects at least annually according to the requirements in § 63.7917(c).
(3) Repairing defects according to the requirements in § 63.7917(e).
(4) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(e) You must demonstrate continuous compliance for each transfer system that is enclosed and vented to a control device according to § 63.7915(c)(3) by meeting the requirements in paragraphs (e)(1) through (5) of this section.
(1) Operating and maintaining the enclosure to ensure that the internal pressure in the vapor headspace in the enclosure is maintained continuously at a level less than atmospheric pressure when the control device is operating.
(2) Inspecting the enclosure and its closure devices for defects at least annually according to the requirements in § 63.7918(d).
(3) Repairing defects according to the requirements in § 63.7918(e).
(4) Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
(5) Keeping records to document compliance with the requirements according to the requirements in § 63.7952.
[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69018, Nov. 29, 2006]