Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Checkout our iOS App for a better way to browser and research.

§ 463.22 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the effluent limitations guidelines (i.e., mass of pollutant discharged) representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available, which are calculated by multiplying the average process water usage flow rate for the cleaning water processes at a point source times the following pollutant concentrations:

Expand Table

Subpart B

[Cleaning water]

Concentration used to calculate BPT effluent limitations
Pollutant or pollutant property Maximum for any 1 day (mg/l) Maximum for monthly average (mg/l)
BOD5 49 22
Oil and grease 71 17
TSS 117 36
pH (1) (1)

The permit authority will obtain the average process water usage flow rate for the cleaning water processes from the permittee.