Effluent limitations attainable by the application of the best practicable control technology currently available (BPT).

Checkout our iOS App for a better way to browser and research.

§ 445.11 Effluent limitations attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations which represent the application of BPT:

Expand Table

Effluent Limitations

Regulated parameter Maximum daily1 Maximum monthly avg.1
BOD5 220 56
TSS 88 27
Ammonia (as N) 10 4.9
α-Terpineol 0.042 0.019
Aniline 0.024 0.015
Benzoic acid 0.119 0.073
Naphthalene 0.059 0.022
p-Cresol 0.024 0.015
Phenol 0.048 0.029
Pyridine 0.072 0.025
Arsenic 1.1 0.54
Chromium 1.1 0.46
Zinc 0.535 0.296
pH (2) (2)

[65 FR 3048, Jan. 19, 2000; 65 FR 14344, Mar. 16, 2000]


Download our app to see the most-to-date content.