Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations which represent the application of BPT:
Effluent Limitations
| Regulated parameter | Maximum daily1 | Maximum monthly avg.1 |
|---|---|---|
| BOD5 | 220 | 56 |
| TSS | 88 | 27 |
| Ammonia (as N) | 10 | 4.9 |
| α-Terpineol | 0.042 | 0.019 |
| Aniline | 0.024 | 0.015 |
| Benzoic acid | 0.119 | 0.073 |
| Naphthalene | 0.059 | 0.022 |
| p-Cresol | 0.024 | 0.015 |
| Phenol | 0.048 | 0.029 |
| Pyridine | 0.072 | 0.025 |
| Arsenic | 1.1 | 0.54 |
| Chromium | 1.1 | 0.46 |
| Zinc | 0.535 | 0.296 |
| pH | (2) | (2) |
[65 FR 3048, Jan. 19, 2000; 65 FR 14344, Mar. 16, 2000]