Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Checkout our iOS App for a better way to browser and research.

§ 435.42 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30-125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Expand Table

BPT Effluent Limitations - Oil and Grease

[In milligrams per liter]

Pollutant parameter waste source Maximum for any 1 day Average of values for 30 consecutive days shall not exceed Residual chlorine minimum for any 1 day
Produced water 72 48 NA
Deck drainage (1) (1) NA
Water-based:
Drilling fluids (1) (1) NA
Drill Cuttings (1) (1) NA
Non-aqueous:
Drilling fluids No discharge No discharge NA
Drill Cuttings (1) (1) NA
Well treatment, workover, and completion fluids (1) (1) NA
Sanitary:
M10 NA NA 2 1
M9IM3 NA NA NA
Domestic3 NA NA NA
Produced sand Zero discharge Zero discharge NA

[61 FR 66125, Dec. 16, 1996, as amended at 66 FR 6916, Jan. 22, 2001; 77 FR 29846, May 18, 2012]