Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Checkout our iOS App for a better way to browser and research.

§ 430.92 Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT), except that non-continuous dischargers shall not be subject to the maximum day and average of 30 consecutive days limitations but shall be subject to annual average effluent limitations:

Expand Table

Subpart I

[BPT effluent limitations]

Pollutant or pollutant property Kg/kkg (or pounds per 1,000 lb) of
product
Continuous dischargers Non-continuous dischargers (annual
average)
Maximum for any 1 day Average of daily values for 30 consecutive days
BOD5 18.1 9.4 5.3
TSS 24.05 12.95 7.12
pH (1) (1) (1)


Download our app to see the most-to-date content.