Effluent limitations representing the degree of effluent reduction attainable by the application of best available technology economically achievable (BAT).

Checkout our iOS App for a better way to browser and research.

§ 430.54 Effluent limitations representing the degree of effluent reduction attainable by the application of best available technology economically achievable (BAT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).

(a)

(1) The following effluent limitations apply to all dischargers in the calcium-, magnesium-, or sodium-based sulfite pulp segment:

Expand Table

Subpart E

[Production of Calcium-, Magnesium-, or Sodium-based Sulfite Pulps]

Pollutant or pollutant property BAT effluent limitations
Continuous dischargers Non-continuous dischargers
Maximum for any 1 day Monthly average Maximum for any 1 day Annual average
kg/kkg (or pounds per 1,000 lb) of product
AOX <MLa (b) <MLa (b)
COD (c) (c) (c) (c)

(2)

(i) The following effluent limitations apply to all dischargers in the ammonium-based sulfite pulp segment:

Expand Table

Subpart E - Production of Ammonium-Based Sulfite Pulps

Pollutant or pollutant property BAT effluent limitations
Maximum for any 1 day Monthly average
TCDDa <MLb (c)
TCDFa <MLb (c)
Chloroforma (d) (c)
Trichlorosyringola <MLb (c)
3,4,5-trichlorocatechola <MLb (c)
3,4,6-trichlorocatechola <MLb (c)
3,4,5-trichloroguaiacola <MLb (c)
3,4,6-trichloroguaiacola <MLb (c)
4,5,6-trichloroguaiacola <MLb (c)
2,4,5-trichlorophenola <MLb (c)
2,4,6-trichlorophenola <MLb (c)
Tetrachlorocatechola <MLb (c)
Tetrachloroguaiacola <MLb (c)
2,3,4,6-tetrachlorophenola <MLb (c)
Pentachlorophenola <MLb (c)
Expand Table
Continuous dischargers Non-continuous
dischargers
Maximum for any 1 day Monthly
average
Maximum for any 1 day Annual
average
kg/kkg (or pounds per 1,000 lb) of product
AOX (d) (d) (d) (d)
COD (d) (d) (d) (d)

(ii) The following effluent limitations apply to all dischargers in the ammonium-based sulfite pulp segment with respect to each fiber line that uses exclusively TCF bleaching processes, as disclosed by the discharger in its NPDES permit application under 40 CFR 122.21(g)(3) and certified under 40 CFR 122.22:

Expand Table

Subpart E - Production of Ammonium-Based Sulfite Pulps

Pollutant or pollutant property BAT effluent limitations (TCF)
Continuous dischargers Non-continuous dischargers
Maximum for any 1 day Monthly average Maximum for any 1 day Annual average
kg/kkg (or pounds per 1,000 lb) of product
AOX <MLa (b) <MLa (b)
COD (c) (c) (c) (c)

(3)

(i) The following effluent limitations apply to all dischargers in the specialty grade pulp segment:

Expand Table

Subpart E - Production of Specialty Grade Sulfite Pulps

Pollutant or pollutant property BAT effluent limitations
Maximum for any 1 day Monthly Average
TCDDa <MLb (c)
TCDFa <MLb (c)
Chloroforma (d) (c)
Trichlorosyringola <MLb (c)
3,4,5-trichlorocatechola <MLb (c)
3,4,6-trichlorocatechola <MLb (c)
3,4,5-trichloroguaiacola <MLb (c)
3,4,6-trichloroguaiacola <MLb (c)
4,5,6-trichloroguaiacola <MLb (c)
2,4,5-trichlorophenola <MLb (c)
2,4,6-trichlorophenola <MLb (c)
Tetrachlorocatechola <MLb (c)
Tetrachloroguaiacola <MLb (c)
2,3,4,6-tetrachlorophenola <MLb (c)
Pentachlorophenola <MLb (c)
Expand Table
Continuous dischargers Non-continuous
dischargers
Maximum for any 1 day Monthly average Maximum for any 1 day Annual
average
kg/kkg (or pounds per 1,000 lb) of product
AOX (d) (d) (d) (d)
COD (d) (d) (d) (d)

(ii) The following effluent limitations apply to dischargers in the specialty grade pulp segment with respect to each fiber line that uses exclusively TCF bleaching processes, as disclosed by the discharger in its NPDES permit application under 40 CFR 122.21(g)(3) and certified under 40 CFR 122.22:

Expand Table

Subpart E - Production of Specialty Grade Pulps

Pollutant or pollutant property BAT effluent limitations (TCF)
Continuous dischargers Non-continuous dischargers
Maximum for any 1 day Monthly average Maximum for any 1 day Annual average
kg/kkg (or pounds per 1,000 lb) of product
AOX <MLa (b) <MLa (b)
COD (c) (c) (c) (c)

(b) The following additional effluent limitations apply to each discharger subject to this section in accordance with the previous subcatgorization scheme unless it certifies to the permitting authority that it is not using these compounds as biocides. Also, for non-continuous dischargers, concentration limitations (mg/l) shall apply. Concentration limitations will only apply to non-continuous dischargers:

Expand Table

Subpart E

[Supplemental BAT effluent limitations]

Pollutant or pollutant property Maximum for any 1 day
kg/kkg (or pounds per 1,000 lb) of product Milligrams/liter
Pentachlorophenol 0.00058exp(0.017x) ((0.011)(12.67)exp(0.017x))/y
Trichlorophenol 0.0036exp(0.017x) ((0.068)(12.67)exp(0.017x))/y
x = percent sulfite pulp in final product.
y = wastewater discharged in kgal per ton of product.

(c) Pursuant to 40 CFR 122.44(i) and 122.45(h), a discharger must demonstrate compliance with the limitations in paragraphs (a)(2) or (a)(3) of this section, as applicable, by monitoring for all pollutants (except for AOX and COD) at the point where the wastewater containing those pollutants leaves the bleach plant. The permitting authority may impose effluent limitations and/or monitoring requirements on internal wastestreams for any other pollutants covered in this section as appropriate under 40 CFR 122.44(i) and 122.45(h).


Download our app to see the most-to-date content.