The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
(a) Any manufacturing plant which produces incandescent lamp envelopes shall meet the following limitations with regard to the forming operations.
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Metric units (g/kkg of furnace pull) | ||
Oil | 90.0 | 45.0 |
TSS | 90.0 | 45.0 |
pH | (1) | (1) |
English units (lb/1,000 lb of furnace pull) | ||
Oil | 0.09 | 0.045 |
TSS | 0.09 | 0.045 |
pH | (1) | (1) |
(b) Any manufacturing plant which frosts incandescent lamp envelopes shall meet the following limitations with regard to the finishing operations.
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Metric units (g/kkg of product frosted) | ||
Fluoride | 104.0 | 52.0 |
Ammonia | 240.0 | 120.0 |
TSS | 80.0 | 40.0 |
pH | (1) | (1) |
English units (lb/1,000 lb of product frosted) | ||
Fluoride | 0.104 | 0.052 |
Ammonia | 0.24 | 0.12 |
TSS | 0.08 | 0.04 |
pH | (1) | (1) |