Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources:
(a) Galvanizing, terne coatings and other coatings -
(1) Strip, sheet, and miscellaneous products.
Subpart L
Pollutant or pollutant property | Pretreatment standards for new sources | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kg/kkg (pounds per 1,000 lb) of product | ||
Lead | 0.000282 | 0.0000939 |
Zinc | 0.000376 | 0.000125 |
Chromium (hexavalent)1 | 0.0000376 | 0.0000125 |
(2) [Reserved]
(b) Galvanizing and other coatings -
(1) Wire products and fasteners.
Subpart L
Pollutant or pollutant property | Pretreatment standards for new sources | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kg/kkg (pounds per 1,000 lb) of product | ||
Lead | 0.00113 | 0.000376 |
Zinc | 0.00150 | 0.000500 |
Chromium (hexavalent)1 | 0.000150 | 0.0000501 |
(2) [Reserved]
(c) Fume scrubbers.
Subpart L
Pollutant or pollutant property | Pretreatment standards for new sources | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kilograms per day | ||
Lead | 0.0368 | 0.0123 |
Zinc | 0.0491 | 0.0164 |
Chromium (Hexavalent)1 | 0.00490 | 0.00163 |
The above limitations shall be applicable to each fume scrubber associated with any of the coating operations specified above.
[47 FR 23284, May 27, 1982, as amended at 49 FR 21037, May 17, 1984]