Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
(a) Galvanizing, terne coating and other coatings -
(1) Strip, sheet, and miscellaneous products scrubbers.
Subpart L
Pollutant or pollutant property | BAT effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kg/kkg (pounds per 1,000 lb) of product | ||
Lead | 0.00113 | 0.000376 |
Zinc | 0.00150 | 0.000500 |
Chromium (hexavalent)1 | 0.000150 | 0.0000501 |
(2) [Reserved]
(b) Galvanizing and other coatings -
(1) Wire products and fasteners.
Subpart L
Pollutant or pollutant property | BAT effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kg/kkg (pounds per 1,000 lb) of product | ||
Lead | 0.00451 | 0.00150 |
Zinc | 0.00601 | 0.00200 |
Chromium (hexavalent)1 | 0.000601 | 0.000200 |
(2) [Reserved]
(c) Fume scrubbers.
Subpart L
Pollutant or pollutant property | BAT effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kg per day | ||
Lead | 0.0368 | 0.0123 |
Zinc | 0.0491 | 0.0164 |
Chromium (hexavalent)1 | 0.00490 | 0.00163 |
The above limitations shall be applicable to each fume scrubber associated with any of the coating operations specified above.
[47 FR 23284, May 27, 1982, as amended at 49 FR 21036, May 17, 1984]