Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Checkout our iOS App for a better way to browser and research.

§ 415.92 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

(a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart and manufacturing hydrogen peroxide by the oxidation of alkyl hydroanthraquinones must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Expand Table

Subpart I - Hydrogen Peroxide Organic Process

Pollutant or pollutant property BPT limitations
Maximum for any 1 day Average of daily values for 30 consecutive days
Kg/kkg (or pounds per 1,000 lb) of product
TSS 0.80 0.40
TOC 0.44 0.22
pH (1) (1)

(b) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart and manufacturing hydrogen peroxide by the electrolytic process must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Expand Table

Subpart I - Hydrogen Peroxide Electrolyte Process

Pollutant or pollutant property BPT limitations
Maximum for any 1 day Average of daily values for 30 consecutive days
Kg/kkg (or pounds per 1,000 lb) of product
TSS 0.0050 0.0025
Cyanide A 0.00040 0.00020
pH (1) (1)