Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Checkout our iOS App for a better way to browser and research.

§ 415.232 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Expand Table

Subpart W - Aluminum Fluoride

BPT effluent limitations Pollutant or pollutant property
Maximum for any 1 day Average of daily values for 30 consecutive days
Kg/kkg (or pounds per 1,000 lb) of product
TSS 2.4 1.2
Fluoride (T) 1.3 0.63
Chromium (T) 0.015 0.0045
Nicket (T) 0.0079 0.0024
pH (1) (1)

[47 FR 28278, June 29, 1982, as amended at 47 FR 55227, Dec. 8, 1982]


Download our app to see the most-to-date content.