(a) Under § 51.50, every environmental report prepared for the construction permit stage or early site permit stage or combined license stage of a light-water-cooled nuclear power reactor, and submitted on or after September 4, 1979, shall take Table S-3, Table of Uranium Fuel Cycle Environmental Data, as the basis for evaluating the contribution of the environmental effects of uranium mining and milling, the production of uranium hexafluoride, isotopic enrichment, fuel fabrication, reprocessing of irradiated fuel, transportation of radioactive materials and management of low-level wastes and high-level wastes related to uranium fuel cycle activities to the environmental costs of licensing the nuclear power reactor. Table S-3 shall be included in the environmental report and may be supplemented by a discussion of the environmental significance of the data set forth in the table as weighed in the analysis for the proposed facility.
(b) Table S-3.
Table S-3 - Table of Uranium Fuel Cycle Environmental Data1
[Normalized to model LWR annual fuel requirement [WASH-1248] or reference reactor year [NUREG-0116]]
Environmental considerations | Total | Maximum effect per annual fuel requirement or reference reactor year of model 1,000 MWe LWR |
---|---|---|
Natural Resource Use | ||
Land (acres): | ||
Temporarily committed2 | 100 | |
Undisturbed area | 79 | |
Disturbed area | 22 | Equivalent to a 110 MWe coal-fired power plant. |
Permanently committed | 13 | |
Overburden moved (millions of MT) | 2.8 | Equivalent to 95 MWe coal-fired power plant. |
Water (millions of gallons): | ||
Discharged to air | 160 | = 2 percent of model 1,000 MWe LWR with cooling tower. |
Discharged to water bodies | 11,090 | |
Discharged to ground | 127 | |
Total | 11,377 | <4 percent of model 1,000 MWe LWR with once-through cooling. |
Fossil fuel: | ||
Electrical energy (thousands of MW-hour) | 323 | <5 percent of model 1,000 MWe LWR output. |
Equivalent coal (thousands of MT) | 118 | Equivalent to the consumption of a 45 MWe coal-fired power plant. |
Natural gas (millions of scf) | 135 | <0.4 percent of model 1,000 MWe energy output. |
Effluents - Chemical (MT) | ||
Gases (including entrainment):3 | ||
SOX | 4,400 | |
NOX4 | 1,190 | Equivalent to emissions from 45 MWe coal-fired plant for a year. |
Hydrocarbons | 14 | |
CO | 29.6 | |
Particulates | 1,154 | |
Other gases: | ||
F | .67 | Principally from UF6 production, enrichment, and reprocessing. Concentration within range of state standards - below level that has effects on human health. |
HCl | .014 | |
Liquids: | ||
SO−4 NO−3 Fluoride Ca+ C1− Na+ NH3 Fe |
9.9 25.8 12.9 5.4 8.5 12.1 10.0 .4 |
From enrichment, fuel fabrication, and reprocessing steps. Components that constitute a potential for adverse environmental effect are present in dilute concentrations and receive additional dilution by receiving bodies of water to levels below permissible standards. The constituents that require dilution and the flow of dilution water are: NH3 - 600 cfs., NO3 - 20 cfs., Fluoride - 70 cfs. |
Tailings solutions (thousands of MT) | 240 | From mills only - no significant effluents to environment. |
Solids | 91,000 | Principally from mills - no significant effluents to environment. |
Effluents - Radiological (curies) | ||
Gases (including entrainment): | ||
Rn-222 | Presently under reconsideration by the Commission. | |
Ra-226 | .02 | |
Th-230 | .02 | |
Uranium | .034 | |
Tritium (thousands) | 18.1 | |
C-14 | 24 | |
Kr-85 (thousands) | 400 | |
Ru-106 | .14 | Principally from fuel reprocessing plants. |
I-129 | 1.3 | |
I-131 | .83 | |
Tc-99 | Presently under consideration by the Commission. | |
Fission products and transuranics | .203 | |
Liquids: | ||
Uranium and daughters | 2.1 | Principally from milling - included tailings liquor and returned to ground - no effluents; therefore, no effect on environment. |
Ra-226 | .0034 | From UF6 production. |
Th-230 | .0015 | |
Th-234 | .01 | From fuel fabrication plants - concentration 10 percent of 10 CFR 20 for total processing 26 annual fuel requirements for model LWR. |
Fission and activation products | 5.9 × 10−6 | |
Solids (buried on site): | ||
Other than high level (shallow) | 11,300 | 9,100 Ci comes from low level reactor wastes and 1,500 Ci comes from reactor decontamination and decommissioning - buried at land burial facilities. 600 Ci comes from mills - included in tailings returned to ground. Approximately 60 Ci comes from conversion and spent fuel storage. No significant effluent to the environment. |
TRU and HLW (deep) | 1.1 × 107 | Buried at Federal Repository. |
Effluents - thermal (billions of British thermal units) | 4,063 | <5 percent of model 1,000 MWe LWR. |
Transportation (person-rem): | ||
Exposure of workers and general public | 2.5 | |
Occupational exposure (person-rem) | 22.6 | From reprocessing and waste management. |
[49 FR 9381, Mar. 12, 1984; 49 FR 10922, Mar. 23, 1984, as amended at 67 FR 77652, Dec. 19, 2002; 72 FR 49512, Aug. 28, 2007]